UV Curing
Opticure LED Cube
2min

Be sure your part is completely dry before curing.
- Put on a new pair of gloves.
- Your gloves will be soiled from washing your part.
- Press SET button. The display will show ‘SEt.1’ with the cure time in red letters below.
- Use arrow buttons to set cure time according to the resin specific protocols (1.00 = 1 minute 00 seconds).
- Place the parts to be cured in the center of the tray.
- Close the door.
- Press the blue start button.
- Rotate the part and repeat until all surfaces have received UV light.
- Since the Opticure LED Cube does not produce heat, pausing between curing each side is not necessary.

If you open the door, the UV lamp turns off, but turns back on the when the door is closed.