Dental Materials
Vita Vionic Try-In Resin
17 min
overview vita vionic try in resin is a 3d printing solution that offers cost effective, fast, and efficient production of a range of dental prosthetics cost effective fast and cost effective production of immediate, replacement and final dentures, as well as temporary crowns/bridges using 3d printing efficient reliable, reproducible fabrication of multiple dentures in a single process accelerated production and quality assurance through automated, validated processes and material properties process secure benefit from perfected matched materials with proven vita quality count on reliable workflows from a single source, combined with validated printers and post curing units vita vionic try in print carbon has validated the following shades a2 this resin is not currently compatible with the docid\ iffh3q8 wlk liqr87bd5 resource links https //www carbon3d com/materials/try in resin https //www vita zahnfabrik com/en/digital dentures/3d printing/vita vionic try in resin 324135,27568 html scroll down to 'instructions for use' and click the appropriate region https //www vita zahnfabrik com/en/digital dentures/3d printing/vita vionic try in resin 324135,27568 html scroll down to 'safety data sheets' and click the appropriate region protocol this downloadable handout provides important usage information, including instructions about storage, washing and curing print it out and bring it into the lab! design see ifu above for manufacturer design recommendations digital preparation connect to printer connect to the printer using your web browser open browser carbon recommends the latest version of google chrome type https //print carbon3d com/ in the url field carbon recommends bookmarking this site for later use if you are not automatically logged in, enter your email and password and click log in enter your email and password and click log in if you have multiple printers, click the printer that you wish to use click the printer that you wish to use connect to printer import part import part click new project you can also drag your files from a file browser window and drop it on top of the new project icon enter a new project name in the resin dropdown, select vita vionic try in resin toggle auto nest dentures off only use encrypt project if you want to require a password to access the project note carbon cannot provide support for encrypted projects drag and drop your files into the dotted box dotted box or click browse your files and select them in a file browser window click create after a few moments you will see the main printer interface with your dentures on the platform orientation for detailed information about orienting parts, read docid\ rmnxtq1niahxzoc4bzxwu rotate full arches to approximately vertical to the platform approximately vertical to the platform with the anterior at the platform anterior at the platform supporting see docid\ vubpoaitblm11am9 qj1p for detailed information select the docid\ vubpoaitblm11am9 qj1p tab in the top bar or press shift + s support tab in the bottom bar, toggle docid 1bt3mas8msvxq9cdza67c on and set the angle to 40 degrees also in the bottom bar, set docid 1bt3mas8msvxq9cdza67c to off set part postion to above support overhanging areas with docid\ vubpoaitblm11am9 qj1p support overhangs support t bars with docid\ vubpoaitblm11am9 qj1p nesting dental nesting select the layout tab (shift + l) in the top menu bar under auto layout, select gen2 gen2 usually gives the most efficient packing for dental devices enter at least 1 mm in padding models require a minimum of 1 mm of space between them leave optimize starting rotation unchecked this leaves your parts in their previous orientations leave allowed rotations at the default setting this gives the software maximum flexibility to fit the most possible parts on the build platform press the auto layout button to arrange your parts if necessary, nesting can be changed manually click and drag parts to adjust their position modify z rotation by using the spin tool or manual rotations under the orient tab (shift + o) use the docid 1bt3mas8msvxq9cdza67c as needed to more easily select models and focus on them print controls click print controls print controls or shift + p shift + p in the top menu bar print controls tab slicing set slice thickness to standard (100 µm) standard slicing reducing the slice thickness by choosing the fine (50 µm) or super fine (25 µm) settings will increase print time and may reduce part quality and accuracy project analysis start analysis on the top menu bar, select the project analysis tab (shift + a) press start analysis after a short time, the result of the project analysis will be displayed note the print time print time and the required resin volume required resin volume click add to queue add to queue printing & post processing consult the manufacturer ifu for dispensing, printing, washing, curing, bonding and finishing information https //www vita zahnfabrik com/en/digital dentures/3d printing/vita vionic base resin impact 328539,27568 html scroll down to 'instructions for use' and click the appropriate region questions & support for questions about the resin properties, printing, washing or curing your parts, please contact the vita support team phone +49 7761 562 222 form https //www vita zahnfabrik com/kontakt formular en html for questions about your carbon printer or carbon software settings used for this resin, please contact carbon email mailto\ support\@carbon3d com phone 1 (650) 285 6307 option 2 printer ui on the dashboard, select the prints prints tab select one of the printed projects select one of the printed projects click request help request help in the lower right corner