title: Overcure
slug: troubleshooting/overcure
description: Discover effective solutions for addressing the "Overcure" part defect from Carbon DLS printing. This comprehensive document explains how to identify, troubleshoot, and understand the root causes.
docTags: 
createdAt: 2024-06-14T01:01:32.542Z
---

::::VerticalSplit{layout="left"}
:::VerticalSplitItem
**Overcure**

Additional resin cured at the edges of a slice in the XY plane.
:::

:::VerticalSplitItem


::Image[]{src="https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/-l8Qwxr8CdZ66nujcmPdX_image.png" size="70" width="1080" height="1080" position="center" alt="Overcure" showCaption="false"}
:::
::::

# How to Identify

Overcure can be diagnosed as follows:

- Features appear too large or distorted
- Holes or small features are too small
- Engraved or embossed text appears blurry



::::LinkArray
:::LinkArrayItem{headerType="IMAGE" headerImage="https://api.archbee.com/api/optimize/Nvx7WdIjE2XFpMaBlbCES-PKINJkIcfL4P7blMAMldX-20240812-163127.jpg"}
**Cause** - Inconclusive
:::

:::LinkArrayItem{headerType="IMAGE" headerImage="https://api.archbee.com/api/optimize/Nvx7WdIjE2XFpMaBlbCES-Bz82ydGVrsKreDbb2gQyt-20240812-163134.jpg"}
**Cause** - Inconclusive
:::
::::

# Troubleshooting

:::hint{type="info"}
It is recommended that you review all the possible solutions before taking action to ensure you are pursuing the best course of action.
:::

If the best course of action is not apparent, try the troubleshooting options in the order listed. Refer [here](docId\:pPm8gmeGCY_0fkFwgTCyj) for more tips.

## Process, Material, and Hardware Checks

If any of these conditions apply to your print, take the corrective action and reprint to see if the problem is resolved.

:::ExpandableHeading
### Resin

- Check the expiration date of your resin lot.
- Ensure all two-part resin prints are completed within the resin's pot-life.
- Ensure that one-part resins are emulsified. Invert bottle 5-6 times to distribute pigment.

![Resin](https://res.cloudinary.com/carbon3d/image/upload/Education/Troubleshooting/Part-Defects/_Common-troubleshooting-for-all/Resin-Troubleshooting_v0102_350px-x12.gif)
:::

:::ExpandableHeading
### Hardware

- Ensure all of the **printer's optics are clean&#x20;**&#x66;or a clear path for UV light.
  - Verify the **cassette window&#x20;**&#x69;s cleaned properly, without dust, spots, or streaks.
  - &#x20;Verify the **projector path&#x20;**&#x69;s clean
    - M1/M2 printers - check the deck glass
    - M3/M3 Max/L1 printers - check the projector lens
- Reference cleaning instructions for your printer: [M1/M2 Printer](docId:__6PWz7Jx_jb4L5_xWKOJ) [M3/M3 Max Printer](docId:3YymGGIHdvaOwG01EAY6l) [L1 Printer](docId\:oN8OtjugBxOTH6QMqW2oM)

::Image[]{src="https://api.archbee.com/api/optimize/xcOI3p6O5jO0MVhoHv9rO-bGIUS_C07lH6mw3xHnY7D-20240801-151327.gif" size="80" width="1653" height="1080" position="center" alt="Ensure all of the printer's optics are clean" showCaption="false"}
:::

## Print Preparation or Part Design Adjustments

The following solutions will address print or part-related causes of the defects. Choose among the suggested actions below and select the best approach for your application. Usually only one type of adjustment is needed.

:::::ExpandableHeading
### Layout

::::VerticalSplit{layout="middle"}
:::VerticalSplitItem
Add more space between parts; increase padding in auto-layout.
:::

:::VerticalSplitItem
![Layout](https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/9JG0v1kg84SJqKfF8vR9S_image.png)
:::
::::
:::::

:::ExpandableHeading
### Scale

Use [correction scale](docId:4Z6MFha_0Lh3vOpPv9Jmn) to bring part features into your specification range by adjusting the X and Y scale factors.

Automatic scale factors account for inaccuracies in the majority of cases, but tweaking the scale factor further may help dial in your feature sizes in some cases.
:::

:::ExpandableHeading
### Design

Use [DLS Design Guidelines](docId\:t94PR-A-C0pIhY6LJsWk7) for holes in the XY plane to bring part features into your specification range. Reference the tips for optical effects in [Recommended Feature Sizes](docId\:t94PR-A-C0pIhY6LJsWk7) for horizontal holes (XY).

![Design](https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/vMxeHNmNHubRsXk5p4MYT_image.png)
:::

:::ExpandableHeading
### Print Plan Adjustments

Reference [Print Plan Adjustments](docId\:NxUK0dltz_vemEAU0DIpN) for guidance on the following parameters:

[5 Exposure Parameters](docId\:nunXRrM4bWbawUQk0FrDt)&#x20;

- *Exposure Timing Parameters*
  - Exposure Timing
:::

:::hint{type="info"}
If problems persist, please reach out to [Carbon Support](mailto\:support@carbon3d.com).
:::

# Explanation & Causes

## Explanation

::::VerticalSplit{layout="middle"}
:::VerticalSplitItem
**Overcure - XY Plane**

Overcure is caused by light scattering horizontally at the edges of a slice, where the material is thinner and less opaque. This scattered light cures resin adjacent to the part and typically causes an additional 0.010 - 0.075mm of part curing. This effect is more significant in smaller cavities due to higher local temperatures.
:::

:::VerticalSplitItem


![Overcure - XY Plane](https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/UdpAjZQ_u_VPrzTXcA-RD_image.png)
:::
::::

## Causes

### Print Preparation or Part Design

::::VerticalSplit{layout="middle"}
:::VerticalSplitItem
How the part is **oriented**, **supported**, or **designed&#x20;**&#x69;s causing the defect.
:::

:::VerticalSplitItem
![Print Preparation or Part Design Cause](https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/LhaBjVT_Yxhp03FPtHLyF_orient-and-support-quick-view-v0101-xxs.gif)
:::
::::

| Root Issue | Problem                      | Why Defect Presents                                                                        |
| ---------- | ---------------------------- | ------------------------------------------------------------------------------------------ |
| Layout     | Parts are too close together | When parts are not spaced properly, light can scatter causing more overcure than expected. |

### Hardware

::::VerticalSplit{layout="middle"}
:::VerticalSplitItem
::Image[]{src="https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/cNMDprn99RIqCfoLiaEF4_hardware-xs.png" size="80" width="738" height="600" position="center" alt="Hardware" showCaption="false"}
:::

:::VerticalSplitItem
The printer, cassette, or platform is **dirty** or requires **maintenance&#x20;**&#x74;o resolve the defect.

Occasionally, a defect may indicate the printer requires servicing by a Carbon engineer.
:::
::::

| Root Issue | Problem                                                                | Why Defect Presents                                                                        |
| ---------- | ---------------------------------------------------------------------- | ------------------------------------------------------------------------------------------ |
| Cleaning   | Cassette window is dirty                                               | Dust, spots, or streaks can cause UV light to scatter causing more overcure than expected. |
| Cleaning   | - Deck glass is dirty (M1/M2)
- Projector lens is dirty (M3/M3 Max/L1) | Dust, spots, or streaks can cause UV light to scatter causing more overcure than expected. |

### Resin

::::VerticalSplit{layout="middle"}
:::VerticalSplitItem
The printing material is **expired**, beyond the printing range in its **pot-life**, or has been **improperly mixed**, causing abnormalities in the print.
:::

:::VerticalSplitItem
![Resin](https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/XGHMl6juLeAliKkQ8uIOF_resins-hero-image-v2.jpg)
:::
::::

| Root Issue    | Problem                  | Why Defect Presents                                                                                                                    |
| ------------- | ------------------------ | -------------------------------------------------------------------------------------------------------------------------------------- |
| Expired       |                          | Resin that is expired may not mix properly which could cause light to scatter and create more overcure than expected.                  |
| Past pot-life |                          | Resin that is past its pot-life may begin to partially cure which could cause light to scatter and create more overcure than expected. |
| Mixing        | One-part resin not mixed | Pigment that is not fully emulsified in the resin could cause light to scatter and create more overcure than expected.                 |

### Print Plan Adjustments

::::VerticalSplit{layout="middle"}
:::VerticalSplitItem
![Print Plan Adjustments](https://api.archbee.com/api/optimize/3CesIL2dYMCHPZvRjp8S0/BzaP59syjyUMWREOHSLmE_print-plan-adjustments-v142.png)
:::

:::VerticalSplitItem
[Print Plan Adjustments](docId\:NxUK0dltz_vemEAU0DIpN) adjust the print plan to optimize mid to high volume production and/or address part defects.&#x20;

In doing so, adjustment may both **prevent or cause defects**. Below are adjustments that can cause this defect.
:::
::::

| Printing Stage | Parameter Type  | Type of Adjustment                        | Why Defect Presents                 |
| -------------- | --------------- | ----------------------------------------- | ----------------------------------- |
| 5 Exposure     | Exposure Timing | <font color="#05a9f4">**Increase**</font> | More UV exposure increases overcure |